PANDUIT: Electrical Full Line
ELECTRICAL SOLUTIONS C2.74 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Cable Fill Capacities for Cove Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the cable installation methods, straightness of cables, etc. Cable fill #1: Open channel without devices. A = 5.4 in. 2 Cable fill #2: Open channel with wire retainer. A = 5.0 in. 2 Cable fill #3: Divided channel (power and data) with wire retainer and divider wall. 3A = 2.4 in. 2 SPEC = 40% cable fill – The recommended design in cable capacity, leaves room for future moves, adds, and changes. MAX for Data = 60% cable fill – The maximum cable quantity based on cable interweaving and packing factors. MAX for Power cable fill – The maximum of electrical cables based on UL temperature rise test. 3B = 2.4 in. 2 Cable fill #4: Divided channel (power and data) with device box and faceplate. A = 1.6 in. 2 Cable fill #5: Divided channel (power and data) with low profile transition insert. A = 1.8 in. 2 A = 1.4 in. 2 A = 2.4 in. 2 AWG dimensions represent typical outer cable diameter in inches. CR-SR-Cove-Wirefill1 Raceway Type and Configuration Fill Area (In.²) Electrical Cables Data Grade Cables Data Grade Cables Audio/Video Fiber Optic Cable 14 AWG 12 AWG 10 AWG 24 AWG/UTP CM 24 AWG/UTP CM RG6 2 Strand THHN/T90 Category 6 Category 6A 0.111 0.130 0.164 Dia. = 0.250 Dia. = 0.330 Dia. = 0.275 Dia. = 0.175 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX (UL Temp Rise Test) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) 1. WCM35: No devices. 5.4 50 40 30 44 66 25 37 36 54 89 134 2. WCM35: Using wire retainer – no devices. 5.0 50 40 30 40 61 23 35 33 50 83 124 3A. WCM35: Power and data using wire retainer and divider wall. 2.4 — — — 19 29 11 16 16 24 39 59 3B. 2.4 30 25 20 — — — — — — — — 4A. WCM35: Power and data using device box and faceplate adapter. 1.6 — — — 13 19 7 11 10 16 26 39 4B. 1.4 25 25 20 — — — — — — — — 5A. WCM35: Power and data using low profile transition insert. 1.8 25 25 20 — — — — — — — — 5B. 2.4 — — — 20 30 11 17 16 25 41 62
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjg1MjI=