PANDUIT: Electrical Full Line

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS C3.43 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Recommended Tubing Size for Common Wire Types Based on Location For Insulated Wire, Non-Insulated Wire, and Insulated Wire with Copper Connectors Instructions for Tube Selection: 1) Determine location type. LOCATION: DRY: A location not normally subject to dampness or wetness. A location classified as dry may be temporarily subject to dampness or wetness, as in the case of a building under construction. DAMP: Partially protected locations under canopies, marquees, roofed open porches and like locations, and interior locations subject to moderate degrees of moisture, such as some basements, barns, and cold-storage warehouses. WET: Installations underground or in concrete slabs or masonry in direct contact with the earth, and locations subject to saturation with water or other liquids, such as vehicle washing areas, and locations exposed to weather and unprotected. 2) Match wire size to location type under required application – insulated wire, non-insulated wire, or insulated wire with copper connectors. 3) Read corresponding part number. 4) Part numbers with “-Y” are packages containing 6 inch pieces. Part numbers with “-48” are 48 inch pieces. 5) Part numbers shown below are for black heat shrink. Sizing information is based on the following wire types: MTW, THHN, THWN, TFN, THW, TW, TF, RHW, RH, RHH and UL 1015. THHN is the most common wire type. Portions reprinted with permission from NFPA, the National Electrical Code* Handbook, Copyright 1996, National Fire Protection Association, Quincy, MA 02269. *All rights reserved. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA 02269. Wire Size Insulated Wire with Copper Connector Uninsulated Wire Dry-Shrink ™ Damp-Shrink ™ Wet-Shrink ™ Dry-Shrink ™ Damp-Shrink ™ Wet-Shrink ™ 24 HSTT09-Y HSTTA19-Y — — — — 22 HSTT09-Y HSTTA19-Y — HSTT05-Y — — 20 HSTT12-Y HSTTA19-Y — HSTT05-Y — — 18 HSTT12-Y HSTTA19-Y — HSTT06-Y — — 16 HSTT19-Y HSTTA25-Y — HSTT09-Y — — 14 HSTT19-Y HSTTA25-Y — HSTT09-Y HSTTA19-Y — 12 HSTT25-Y HSTTA38-Y — HSTT012-Y HSTTA19-Y — 10 HSTT25-Y HSTTA38-Y HST0.4-48-5Y HSTT19-Y HSTTA25-Y — 8 HSTT38-Y HSTTA50-Y HST0.4-48-5Y HSTT19-Y HSTTA25-Y — 6 HSTT50-Y HSTTA50-Y HST0.8-48-5Y HSTT25-Y HSTTA38-Y HST0.4-48-5Y 4 HSTT50-Y HSTTA75-Y HST0.8-48-5Y HSTT38-Y HSTTA50-Y HST0.4-48-5Y 3 HSTT50-Y HSTTA75-Y HST0.8-48-5Y HSTT38-Y HSTTA50-Y HST0.4-48-5Y 2 HSTT75-Y HSTTA100-Y HST1.1-48-5Y HSTT38-Y HSTTA50-Y HST0.8-48-5Y 1 HSTT75-Y HSTTA100-Y HST1.1-48-5Y HSTT50-Y HSTTA75-Y HST0.8-48-5Y 1/0 HSTT75-Y HSTTA100-Y HST1.1-48-5Y HSTT50-Y HSTTA75-Y HST0.8-48-5Y 2/0 HSTT100-Y HSTTA150-Y HST1.5-48-5Y HSTT50-Y HSTTA100-Y HST0.8-48-5Y 3/0 HSTT100-Y HSTTA150-Y HST1.5-48-5Y HSTT75-Y HSTTA100-Y HST1.1-48-5Y 4/0 HSTT100-Y HSTTA150-Y HST1.5-48-5Y HSTT75-Y HSTTA100-Y HST1.1-48-5Y 250 HSTT100-Y HSTTA150-Y HST2.0-48-2Y HSTT100-Y HSTTA100-Y HST1.1-48-5Y 300 HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y HSTT100-Y HSTTA150-Y HST1.5-48-5Y 350 HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y HSTT100-Y HSTTA150-Y HST1.5-48-5Y 400 HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y HSTT100-Y HSTTA150-Y HST1.5-48-5Y 500 HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y HSTT100-Y HSTTA150-Y HST1.5-48-5Y 600 HSTT200-48-5 HSTTA150-Y HST2.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 700 HSTT200-48-5 HSTTA150-Y HST2.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 750 HSTT200-48-5 HSTTA150-Y HST3.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 800 HSTT200-48-5 HSTTA150-Y HST3.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 900 HSTT200-48-5 — HST3.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 1000 HSTT200-48-5 — HST3.0-48-2Y HSTT150-48-5 HSTTA150-Y HST2.0-48-2Y 1250 HSTT200-48-2 — HST3.0-48-2Y HSTT200-48-5 HSTTA150-Y HST2.0-48-2Y 1500 HSTT300-48-2 — HST3.0-48-2Y HSTT200-48-5 — HST2.0-48-2Y 1750 HSTT300-48-2 — HST3.0-48-2Y HSTT200-48-5 — HST2.0-48-2Y 2000 HSTT300-48-2 — HST3.0-48-2Y HSTT200-48-5 — HST2.0-48-2Y

RkJQdWJsaXNoZXIy Mjg1MjI=