PANDUIT: Electrical Full Line

D2.47 For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Code Conductor, Two-Hole, Long Barrel with Window Lug Part Number Figure No. Copper Conductor Size Stud Hole Size (In.) Stud Hole Spacing (In.) Figure Dimensions (In.) Panduit Color Code Panduit Die Index No. ‡ Burndy Die Index No. ‡ T&B Die Index No. ‡ Wire Strip Length (In.) Std. Pkg. Qty. W B T L LCC10-14JAW-L* 2 #14 – 10 AWG STR, #12 – 10 AWG SOL 1/4 .50 – .63 .42 .53 .05 1.93 — — — — 9/16 50 LCC10-14AW-L * 1 1/4 .63 .42 .53 .05 1.93 — — — — 9/16 50 LCC10-14BW-L * 1 1/4 .75 .42 .53 .05 2.06 — — — — 9/16 50 LCC8-10AW-L 1 #8 AWG #10 .63 .41 .70 .08 2.01 Red P21 49 21 3/4 50 LCC8-10BW-L 1 #10 .75 .41 .70 .08 2.14 Red P21 49 21 3/4 50 LCC8-10ABW-L 2 #10 .63 – .75 .41 .70 .08 2.14 Red P21 49 21 3/4 50 LCC8-14AW-L 1 1/4 .63 .48 .70 .07 2.10 Red P21 49 21 3/4 50 LCC8-14BW-L 1 1/4 .75 .48 .70 .07 2.23 Red P21 49 21 3/4 50 LCC8-14ABW-L 2 1/4 .63 – .75 .48 .70 .07 2.23 Red P21 49 21 3/4 50 LCC8-14DW-L 1 1/4 1.00 .48 .70 .07 2.48 Red P21 49 21 3/4 50 LCC8-38DW-L 1 3/8 1.00 .60 .70 .05 2.70 Red P21 49 21 3/4 50 LCC6-10AW-L 1 #6 AWG #10 .63 .46 1.07 .08 2.40 Blue P24 7 24 1 1/8 50 LCC6-10BW-L 1 #10 .75 .46 1.07 .08 2.52 Blue P24 7 24 1 1/8 50 LCC6-10ABW-L 2 #10 .63 – .75 .46 1.07 .08 2.52 Blue P24 7 24 1 1/8 50 LCC6-14JW-L 1 1/4 .50 .48 1.07 .08 2.36 Blue P24 7 24 1 1/8 50 LCC6-14AW-L 1 1/4 .63 .48 1.07 .08 2.49 Blue P24 7 24 1 1/8 50 LCC6-14JAW-L 2 1/4 .50 – .63 .48 1.07 .08 2.49 Blue P24 7 24 1 1/8 50 LCC6-14BW-L 1 1/4 .75 .48 1.07 .08 2.61 Blue P24 7 24 1 1/8 50 LCC6-14DW-L 1 1/4 1.00 .48 1.07 .08 2.86 Blue P24 7 24 1 1/8 50 LCC6-14BDW-L 2 1/4 .75 – 1.00 .48 1.07 .08 2.86 Blue P24 7 24 1 1/8 50 LCC6-14EW-L 1 1/4 1.25 .48 1.07 .08 3.11 Blue P24 7 24 1 1/8 50 LCC6-14W-L 1 1/4 1.75 .48 1.07 .08 3.61 Blue P24 7 24 1 1/8 50 LCC6-56BW-L 1 5/16 .75 .56 1.07 .07 2.73 Blue P24 7 24 1 1/8 50 LCC6-38BW-L 1 3/8 .75 .62 1.07 .06 2.83 Blue P24 7 24 1 1/8 50 LCC6-38CW-L 1 3/8 .88 .62 1.07 .06 2.96 Blue P24 7 24 1 1/8 50 LCC6-38DW-L 1 3/8 1.00 .62 1.07 .06 3.08 Blue P24 7 24 1 1/8 50 LCC6-38BDW-L 2 3/8 .75 – 1.00 .62 1.07 .06 3.08 Blue P24 7 24 1 1/8 50 LCC6-12W-L 1 1/2 1.75 .75 1.07 0.07 3.97 Blue P24 7 24 1 1/8 50 • Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance • Inspection window to visually assure full conductor insertion • Color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection • Tin-plated to inhibit corrosion • UL Listed and CSA Certified to 35 KV** and temperature rated to 90°C when crimped with Panduit and specified competitor crimping tools and dies • UL Listed and CSA Certified for wide wire range-taking capability when crimped with Panduit ® Uni-Die ™ Dieless Crimping Tools‡ • Tested by Telcordia – meets NEBS Level 3 • Meets J-STD-607-A and TIA-942 requirements for network systems grounding applications • Available with NEMA hole sizes and spacing W HOLE SPACING T L INSPECTION WINDOW B For Use with Stranded Copper Conductors Type LCC-W ‡See pages D3.62 – D3.65 for tool and die information. *Not tested to NEBS Level 3 requirements. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ◆ NEMA hole sizes and spacing. W HOLE SPACING L B INSPECTION WINDOW T Figure 1 Figure 2: Slotted Table continues on pages D2.48 – D2.49

RkJQdWJsaXNoZXIy Mjg1MjI=