PANDUIT: Electrical Full Line

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS D2.127 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Split Bolt, Aluminum The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended. See page D2.155. ^Not CSA Certified. Two-Bolt Connector, Bronze • Made from lightweight, durable aluminum alloy to resist corrosion and provide premium electrical and mechanical performance • Dual rated for use with aluminum to aluminum, aluminum to copper, and copper to copper conductor combinations • Tin-plated to inhibit corrosion and oxidation • Wide wire range-taking capability minimizes inventory requirements • True hex design for body and nut hex provides correct fit with socket, box, or open end wrenches resulting in proper torquing of electrical connection • Free floating pressure bar separates conductors of dissimilar materials for secure connection on a full range of conductor combinations • UL Listed and CSA Certified for use up to 600 V and UL temperature rated 90°C For Use with Copper and Aluminum Code Conductors Type SBA L W E • Made from high strength bronze for heavy duty connections and to inhibit corrosion • Cap swivels for easy installation of conductors • Rubber washer retains hardware to connector and eliminates loose parts • High strength silicon-bronze hardware provides premium mechanical performance when assembled to conductor • Wide wire range-taking capability minimizes inventory requirements • UL Listed for use up to 600 V and 90°C temperature rated For Use with Copper Code Conductors Type VT L W C H ^ ^ Part Number Max. Run to Max. Tap Min. Run to Min. Tap Max. Run to Min. Tap Figure Dimensions (In.) Std. Pkg. Qty. E W L SBA6-C #6 STR – #6 STR #10 SOL – #10 SOL #6 STR – #10 SOL 0.56 0.75 1.58 100 SBA4-C #4 STR – #4 STR #8 SOL – #10 SOL #4 STR – #10 SOL 0.62 0.81 1.38 100 SBA2-C #2 STR – #2 STR #6 SOL – #8 STR #2 STR – #8 STR 0.69 0.94 1.58 100 SBA1/0-Q 1/0 STR – 1/0 STR #2 STR (Compact) – #8 SOL 1/0 STR – #8 SOL 0.75 1.00 1.92 25 SBA2/0-Q 2/0 STR – 2/0 STR #2 STR (Compact) – #8 STR 2/0 STR – #8 STR 0.88 1.12 1.92 25 SBA4/0-Q 4/0 STR – 4/0 STR #2 STR (Compact) – #6 STR 4/0 STR – #6 STR 1.13 1.49 2.54 25 SBA350-1 350 kcmil – 350 kcmil 1/0 STR (Compact) – #4 STR 350 kcmil – #4 STR 1.50 1.69 3.24 1 SBA500-1 ^ 500 kcmil – 500 kcmil 400 kcmil (Compact) – #2 STR (Compact) 500 kcmil – #2 STR (Compact) 1.73 2.00 3.62 1 Part Number Copper Conductor Size Figure Dimensions (In.) Hex Size (In.) Std. Pkg. Qty. Run Tap L W H C VT-0-Q #2 STR – 1/0 STR #10 STR – 1/0 STR 1.50 1.44 0.94 0.31 1/2 25 VT-1-Q #2 STR – 2/0 STR #10 STR – 2/0 STR 1.50 1.56 1.13 0.31 1/2 25 VT-2-Q 1/0 STR – 4/0 STR #10 STR – 4/0 STR 1.75 1.84 1.34 0.38 9/16 25 VT-3-12 250 kcmil – 350 kcmil #10 STR – 350 kcmil 2.00 2.31 1.63 0.50 3/4 12 VT-4-12 250 kcmil – 500 kcmil #10 STR – 500 kcmil 2.25 2.44 1.69 0.50 3/4 12 VT-5-6 400 kcmil – 800 kcmil 3/0 STR – 800 kcmil 2.50 2.69 1.88 0.50 9/16 6 VT-6-6 500 kcmil – 1000 kcmil 3/0 STR – 1000 kcmil 2.75 3.06 2.25 0.63 15/16 6

RkJQdWJsaXNoZXIy Mjg1MjI=