PANDUIT: Electrical Full Line
ELECTRICAL SOLUTIONS Prime items appear in BOLD . D2.146 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Two-Hole, Vertical Four-Barrel Lug Four-Hole, Four-Barrel Lug • Four barrels provide termination of four conductors • Vertical configuration saves space • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • UL Listed and CSA Certified for use up to 600 V and UL temperature rated 90°C L W HOLE SPACING H2 H1 P T For Use with Stranded Aluminum or Copper Code Conductors Type LAM4SB • Four barrels provide termination of four conductors • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • LAM4LD connector is provided with dual set screws to allow premium clamping of conductor to connector for heavy duty applications • For use up to 600 V and temperature rated 90°C • Available with NEMA hole sizes and spacing HOLE SPACING L W T H P HOLE SPACING For Use with Stranded Aluminum or Copper Code Conductors Type LAM4D The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. W L P T H HOLE SPACING HOLE SPACING The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. ◆ NEMA hole sizes and spacing. Figure 1 Figure 2 Part Number Conductor Size Range Stud Hole Size (In.) Stud Hole Spacing (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H1 H2 T P LAM4SB600-38-1Y #2 AWG – 600 kcmil 3/8 1.38 3/8 4.91 2.47 3. 00 1.88 0.75 2.34 1 LAM4SB750-38-1Y 1/0 AWG – 750 kcmil 3/8 1.38 3/8 4.91 2.84 3 .00 1.88 0.75 2.34 1 Part Number Figure No. Conductor Size Range Stud Hole Size (In.) Stud Hole Spacing (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H T P ◆ LAM4D250-12-1Y 1 # 6 AWG – 250 kcmil 1/2 1.75 5/16 4.25 4.04 1.19 0.31 3.25 1 ◆ LAM4D350-12-1Y 1 # 6 AWG – 350 kcmil 1/2 1.75 5/16 4.50 4.72 1.37 0.31 3.25 1 ◆ LAM4LD600-12-1 2 #2 – 600 kcmil 1/2 1.75 3/8 5.50 5.31 1.50 0.38 3.25 1 ◆ LAM4LD1000-12-1 2 350 – 1000 kcmil 1/2 1.75 3/8 6.19 7.11 1.88 0.56 3.44 1
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjg1MjI=