PANDUIT: Electrical Full Line
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS D3.33 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Crimping Guidelines for Panduit ® StructuredGround ™ Compression Connectors TAP Installation HTAP Cover Installation 1. Locate desired position of TAP along main wire run. Allow clearance for tap wires (and cover installation if applicable). See clear cover table on page D3.13. 2. Strip insulation from wires to the length shown in the TAP table on page D3.14. Use care to avoid damaging the conductors. 3. Position wires in the appropriate tap grooves. 4. For easier installation, apply one of the flame retardant cable ties (provided) around the wires and through the slots in the TAP. The head of the cable tie must be positioned along the side of the TAP as shown in Figure A. Tension and cut off excess length of tie. Additional cable ties may be used adjacent to the TAP to secure the wires. 5. Install the correct dies (see page D3.94) into the crimping tool. Position the locator die into the stationary die holder. Note: The color code and die index number shown on the HTAP and crimping dies must match. 6. Position the TAP against the locator in the stationary die holder of the crimping tool. 7. After crimping, if desired, cut off the cable tie head or remove the entire cable tie. Note: In some cases, the cable tie head must be cut off in order for the crimped connector to fit inside the insulating cover. 1. If labels are being utilized, cut labels to the dimensions shown below. Note: When using a Panduit ® Pan-Ther ™ LS8E printer, the length dimensions can be easily programmed to provide cut-off marks. 2. Position the label(s) in the pockets inside the cover and snap in the label retainer(s) as shown in Figure B. Information can be marked on the matte finish label retainers in lieu of using a separate label. 3. Position one cover half around the crimped connector assembly. Align the second cover half with the first and snap together. 4. Install the two flame retardant cable ties (provided) in the grooved areas on the cover. Tension and cut off excess lengths of ties. Figure A Figure B Cover allows for a clear view of the label and label protection Non-adhesive label may be used Two label retainers provided Pockets for cable tie heads Guides for cable ties Write-on surface on label retainer Label pockets provided Guides for cable ties Crimping Direction Note: Configuration of cover may differ slightly from illustration. Clear Cover Part Number CLRCVR1-1 CLRCVR2-1 CLRCVR3-1 .38 1.56 1.00 .38 1.87 1.25 .38 2.37 1.75 Label Height (Max.) Label Length (Wrap-Around Style) Label Length (Flat Style) Label Size Information
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjg1MjI=