PANDUIT: Electrical Full Line
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) ELECTRICAL SOLUTIONS D2.143 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification One-Hole, Vertical Two-Barrel Lug Two-Hole, Two-Barrel Lug • Dual barrel provides termination of two conductors • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • UL Listed and CSA Certified for use up to 600 V and UL temperature rated 90°C For Use with Stranded Aluminum or Copper Code Conductors Type LAM2SA L W T P H2 H1 • Dual barrel provides termination of two conductors • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • LAM2LB connector provided with dual set screws for premium clamping of conductor to connector for heavy duty applications • UL Listed for use up to 600 V and temperature rated 90°C • Available with NEMA hole sizes and spacing For Use with Stranded Aluminum or Copper Code Conductors Type LAM2B L HOLE SPACING W T P H The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. HOLE SPACING L W P H T Figure 1 Figure 2 The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. *UL Listed and CSA Certified. ◆ NEMA hole sizes and spacing. Part Number Conductor Size Range Stud Hole Size (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H1 H2 T P LAM2SA300-56-3 #6 AWG – 300 kcmil 5/16 5/16 3 .00 1.00 2.00 1.25 0.50 1. 00 3 Part Number Figure No. Conductor Size Range Stud Hole Size (In.) Stud Hole Spacing (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H T P ◆ LAM2B350-12-3Y 1 #6 AWG – 350 kcmil 1/2 1.75 5/16 4.19 1.91 1.28 0.25 3.06 3 ◆ LAM2LB600-12-3 * 2 #2 AWG – 600 kcmil 1/2 1.75 3/8 5.50 2.85 1.50 0.38 3.25 3 ◆ LAM2LB1000-12-3 * 2 500 – 1000 kcmil 1/2 1.75 1/2 6.19 3.48 1.88 0.56 3.44 3
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjg1MjI=