PANDUIT: Electrical Full Line
ELECTRICAL SOLUTIONS Prime items appear in BOLD . D2.144 B2. Cable Accessories C1. Wiring Duct C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors E1. Labeling Systems E2. Labels E3. Pre-Printed & Write-On Markers F. Index B3. Stainless Steel Ties C2. Surface Raceway E5. Lockout/ Tagout & Safety Solutions B1. Cable Ties A. System Overview D3. Grounding Connectors E4. Permanent Identification Two-Hole, Vertical Two-Barrel Lug Two-Hole, Three-Barrel Lug • Dual barrel provides termination of two conductors • Vertical configuration saves space • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • UL Listed and CSA Certified for use up to 600 V and UL temperature rated 90°C W H2 H1 HOLE SPACING L T P For Use with Stranded Aluminum or Copper Code Conductors Type LAM2SB • Triple barrel provides termination of three conductors • Made from high strength, extruded aluminum alloy to provide premium electrical and mechanical performance • Tin-plated to inhibit corrosion • Wide wire range-taking capability minimizes inventory requirements • Inspection window to visually assure full conductor insertion • Plated steel or aluminum set screw provides high strength, durable electrical contact between conductor and connector • LAM3LB connector is provided with dual set screws to allow premium clamping of conductor to connector for heavy duty applications • For use up to 600 V and temperature rated 90°C • Available with NEMA hole sizes and spacing T P W HOLE SPACING L H For Use with Stranded Aluminum or Copper Code Conductors Type LAM3B W HOLE SPACING P T L H2 H1 Figure 1 Figure 2 The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. *UL Listed and CSA Certified. L HOLE SPACING W H T P Figure 1 Figure 2 The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155. **Uses slotted head set screw. ◆ NEMA hole sizes and spacing. Part Number Figure No. Conductor Size Range Stud Hole Size (In.) Stud Hole Spacing (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H1 H2 T P LAM2SB600-38-1Y * 1 #2 AWG – 600 kcmil 3/8 1.38 3/8 4.91 1.50 3 .00 1.88 0.75 2.34 1 LAM2SB750-38-1Y * 1 1/0 AWG – 750 kcmil 3/8 1.38 3/8 4.91 1.50 3 .00 1.88 0.75 2.34 1 LAM2SSB500-141Y 2 4/0 AWG – 500 kcmil 1/4 0.69 1/2 2.91 1.44 2.38 1.77 0.63 1.69 1 Part Number Figure No. Conductor Size Range Stud Hole Size (In.) Stud Hole Spacing (In.) Hex Key Size (In.) Figure Dimensions (In.) Std. Pkg. Qty. L W H T P LAM3B1/0-38-6Y 1 #14 AWG – 1/0 AWG 3/8 1.00 ** 2.91 2.00 0.88 0.25 2.16 6 ◆ LAM3B3/0-12-3Y 1 #6 AWG – 3/0 AWG 1/2 1.75 1/4 4.25 2.81 1.19 0.31 3.25 3 ◆ LAM3B250-12-1Y 1 #6 AWG – 250 kcmil 1/2 1.75 5/16 4.00 2.82 1.19 0.31 3.00 1 ◆ LAM3B350-12-1Y 1 #6 AWG – 350 kcmil 1/2 1.75 5/16 4.50 3.50 1.38 0.31 3.25 1 ◆ LAM3LB600-12-1 2 #2 AWG – 600 kcmil 1/2 1.75 3/8 5.50 4.32 1.50 0.38 3.25 1 ◆ LAM3LB1000-121Y 2 500 kcmil – 1000 kcmil 1/2 1.75 1/2 6.19 5.27 1.88 0.56 3.44 1
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjg1MjI=